End-to-End Fire Protection Solutions for Every Facility
APEX Fire Protection Division (FPD) specializes in delivering comprehensive fire detection and suppression solutions across industrial, commercial, and residential sectors. Every system is designed in compliance with NFPA, HCIS, and SBC standards, utilizing UL / FM / LPCB certified equipment.
WHAT WE DO
- Fire protection system design & engineering
- Supply of UL / FM / LPCB certified equipment
- Installation & system integration
- Testing, commissioning & authority approvals
- Preventive & corrective maintenance services
Fire Detection & Alarm Systems (FDAS)
Fire Detection & Alarm Systems (FDAS) provide early and reliable detection of fire through advanced, intelligent, and addressable technologies. These systems continuously monitor the facility and quickly identify fire conditions, enabling timely alerts and activation of emergency response functions.
Designed in accordance with NFPA 72 (National Fire Alarm and Signaling Code), FDAS ensures effective integration with suppression systems, emergency lighting, and evacuation controls.
KEY FEATURES
- Intelligent addressable detection for precise location identification
- Continuous facility monitoring with instant alarm activation
- Integration with suppression systems, emergency lighting, and evacuation controls
- Suitable for commercial, industrial, and residential facilities
- Ensures compliance with international fire safety regulations
SYSTEM COMPONENTS
- Fire Alarm Control Panels (addressable)
- Smoke Detectors
- Heat Detectors
- Flame Detectors
- Manual Call Points / Pull Stations
- Notification Devices (Bells, Horns, Strobes)
- Field Module Monitors (FMM)
Aspirating Smoke Detection Systems (VESDA / HSSD)
Aspirating Smoke Detection Systems (VESDA / HSSD) provide ultra-early warning fire detection by continuously sampling air through a network of pipes and analyzing it for smoke particles. These high-sensitivity systems can detect fire at a very early stage — even before visible smoke is present.
Compliant with NFPA 72, these systems are ideal for mission-critical environments where early detection is essential to prevent damage and downtime.
KEY FEATURES
- Ultra-early smoke detection — detects before visible smoke forms
- Continuous air sampling through a network of pipes
- High sensitivity — ideal for clean, sensitive environments
- Enhances safety response time and reduces asset damage
- Reliable protection for high-value and mission-critical equipment
IDEAL ENVIRONMENTS
- Data Centers
- Clean Rooms
- Telecom Facilities
- Control Rooms
- Server Rooms & IT Infrastructure
Gaseous Fire Suppression Systems
Gaseous fire suppression systems use clean, non-conductive gases to extinguish fires quickly without leaving any residue or causing damage to sensitive equipment. These systems are ideal for protecting critical environments such as data centers, electrical rooms, control rooms, and telecommunication facilities.
HOW IT WORKS
These systems operate by either reducing oxygen levels below the combustion threshold or interrupting the chemical chain reaction of fire — ensuring fast and effective suppression while maintaining safety requirements for the protected space.
KEY BENEFITS
- No residue — safe for sensitive equipment
- Rapid fire suppression with minimal downtime
- Non-conductive — safe for electrical environments
- Reliable protection for high-value assets
Kitchen Hood Fire Suppression Systems
Kitchen Hood Fire Suppression Systems are specially designed wet-chemical systems that provide rapid and effective fire protection for commercial cooking environments. These systems automatically detect and suppress fires originating from cooking equipment, grease-laden vapors, and exhaust ducts.
Designed in accordance with NFPA 96 (Ventilation Control and Fire Protection of Commercial Cooking Operations).
HOW IT WORKS
The system discharges a wet-chemical agent that cools the fire and forms a protective layer to prevent re-ignition, ensuring rapid containment of kitchen fires.
KEY FEATURES
- Automatic detection and suppression of cooking fires
- Wet-chemical agent cools flames and seals fuel surface
- Prevents re-ignition after initial suppression
- Ensures safety, compliance, and uninterrupted operations
APPLICATIONS
- Restaurants & Cafeterias
- Hotels & Resorts
- Industrial & Institutional Kitchens
- Food Processing Facilities
Kitchen Hood Fire Suppression Systems
Sprinkler, Pre-Action, and Deluge Systems are automatic water-based fire suppression systems designed to control or extinguish fires efficiently. These systems activate either by heat (sprinklers) or through detection systems (pre-action and deluge), ensuring rapid response to fire incidents.
SYSTEM TYPES
Sprinkler System
- Combination of detection signal + sprinkler operation
- Ideal For Sensitive areas (data centers, control rooms)
Pre-Action System
- Automatically activated by heat at individual heads
- Ideal For Commercial & residential buildings
Deluge System
- Open nozzle system activated by detection signal
- Ideal For High-hazard / high-risk industrial areas
Water Spray System
- Fixed piping with spray nozzles over protected surface
- Ideal For Fuel oil tanks and high-risk industrial areas
APPLICABLE STANDARDS
- NFPA 13 — Installation of Sprinkler Systems
- NFPA 15 — Water Spray Fixed Systems
- NFPA 25 — Inspection, Testing and Maintenance of Water-Based Fire Protection Systems
Foam-Based Fire Protection Systems
Foam-Based Fire Protection Systems are specialized suppression systems designed to effectively control and extinguish fires involving flammable and combustible liquids. A foam solution blankets the fuel surface, suppressing vapors, cooling the fire, and preventing re-ignition.
SYSTEM TYPES
Foam Monitor
- Supplementary foam discharge for spill fires around tanks
Foam Hydrant
- Manual foam discharge for tank area protection
Foam Chamber System
- Directs foam flow to oil surface in storage tanks
Foam-Water Deluge System
- Foam-water spray for large area protection
APPLICATIONS
- Fuel & crude oil storage tanks
- Chemical and petrochemical facilities
- Refineries and loading terminals
- Aircraft hangars
- Industrial plants handling flammable liquids
APPLICABLE STANDARDS
- NFPA 11 — Low, Medium, and High Expansion Foam Systems
- NFPA 16 — Foam-Water Sprinkler and Foam-Water Spray Systems
- NFPA 30 — Flammable and Combustible Liquids Code
- NFPA 25 — Inspection, Testing and Maintenance
Fire Pump Systems
Fire Pump Systems are critical components of water-based fire protection networks, designed to provide the required pressure and flow to ensure effective firefighting operations. They support sprinklers, hydrants, hose reels, and other suppression systems.
SYSTEM TYPES
Horizontal Split Case Pump
- Motor or Diesel Driven
End Suction Pump
- Motor Driven
Vertical Turbine Pump
- Motor Driven
Vertical Inline Pump
- Motor Driven
Jockey Pump
- Motor Driven (pressure maintenance)
KEY FUNCTIONS
- Provides required water pressure and flow for all fire protection systems
- Ensures continuous and reliable water supply during fire emergencies
- Supports sprinklers, hydrants, monitors, and hose reel systems
APPLICABLE STANDARDS
- NFPA 20 — Installation of Stationary Pumps for Fire Protection
- NFPA 25 — Inspection, Testing and Maintenance of Water-Based Systems
Fire Hydrant Systems
Fire Hydrant Systems are essential external firefighting systems providing a reliable and readily accessible water supply for firefighting operations. Strategically installed across facilities to support emergency response by fire personnel.
HYDRANT TYPES
Wet Barrel Hydrant
- Water-charged at all times; for warm climate zones
Dry Barrel Hydrant
- Water drains when not in use; for cold/outdoor areas
Underground Hydrant
- Below-grade installation for protected areas
Outdoor Hydrant
- General use to cover whole plant or facility perimeter
RELATED ACCESSORIES
- Post Indicator Valve (PIV) — isolates the water ring main; shows Open/Shut status
- Fire Hose Reels & Nozzles
- Fire Monitors
- Landing Valves
APPLICABLE STANDARDS
- NFPA 24 — Installation of Private Fire Service Mains
- NFPA 291 — Fire Flow Testing and Marking of Hydrants
- NFPA 25 — Inspection, Testing and Maintenance
Fire Hose & Extinguisher Cabinets
Fire Hose & Extinguisher Cabinets are essential first-response firefighting units providing immediate access to firefighting equipment during emergencies. These cabinets house fire hoses, hose reels, nozzles, landing valves, and portable fire extinguishers — enabling quick manual intervention before the arrival of fire services.
CABINET CONTENTS
- Fire Hose (25mm / 40mm / 65mm) — 30m hose sets
- Fire Hose Reel
- Adjustable Variable Fog Nozzle (fog to straight stream to shut-off)
- Landing Valve
- Lock Shield Valve
- Portable Fire Extinguisher
KEY FEATURES
- Provides manual firefighting capability for first response
- Installed in corridors, escape routes, and common areas
- Easy access to essential firefighting equipment
- Enhances safety and emergency preparedness
APPLICABLE STANDARDS
- NFPA 14 — Standpipe and Hose Systems
- NFPA 10 — Portable Fire Extinguishers
- NFPA 1962 — Care, Use and Service Testing of Fire Hose
Fire Extinguishers
Fire Extinguishers are portable firefighting devices designed for immediate response to small fires, helping to control or extinguish fire at its early stage before it spreads. APEX supplies, installs, services, refills, and certifies fire extinguishers for commercial, industrial, and residential applications.
FIRE CLASSES COVERED
Class A
- Ordinary combustibles (wood, cloth, paper, rubber, plastics)
Class B
- Flammable liquids, petroleum products, combustible gases
Class C
- Electrical equipment
Class D
- Combustible metals
Class K
- Cooking oils and fats
OUR SERVICES FOR EXTINGUISHERS
- Supply & installation
- Annual inspection & certification
- Refilling (powder and CO₂)
- Hydrostatic testing
- Maintenance & repair
APPLICABLE STANDARDS
NFPA 10 — Standard for Portable Fire Extinguishers
Fire Protection Valves & Accessories
Fire Protection Valves and Accessories are essential supporting components for all water-based fire protection systems. APEX supplies a comprehensive range of valves and fittings certified for fire protection applications.
PRODUCT RANGE
NRS Gate Valve (Non-Rising Stem)
- Isolation of water supply lines
OS&Y Gate Valve (Outside Stem & Yoke)
- Visible open/closed indicator for sprinkler systems
Post Indicator Valve (PIV)
- Above-ground isolation of underground mains
Butterfly Valve
- Flow control in large-diameter piping